BMU & Façade Access Engineering Articles

Technical articles on building maintenance units, façade access, and fall-protection engineering — inspection, failure modes, acceptance testing, design, investigation, procurement, and retrofit.

01

BMU Inspection and Certification: Who Is Responsible

Who is responsible for BMU inspection and certification, what OSHA 1910.66 and ASME A120.1 actually require, and what the annual certificate does not tell the building owner.

Read article →

02

Common Failure Modes in Building Maintenance Units

How building maintenance units fail: the recurring failure categories in BMU drivetrains, wire rope, structural interfaces, and safety devices, from a field engineer’s perspective.

Read article →

03

BMU Factory & Site Acceptance Testing: What FAT and SAT Verify

What a factory acceptance test (FAT) and site acceptance test (SAT) verify on a building maintenance unit, what each does not verify, and what an owner should hold from both.

Read article →

04

Façade Access Design: The Decisions That Must Be Made Early

Which façade access and fall-protection decisions must be made in early design — geometry, structural provisions, rescue feasibility — and why they harden as the project advances.

Read article →

05

Suspended Access Accidents: What an Engineering Investigation Examines

What an engineering investigation of a suspended access or BMU accident examines — design geometry, acceptance records, inspection scope, configuration — and how it informs standard-of-care questions.

Read article →

06

Buying a BMU from an Overseas Manufacturer: What Protects the Owner

Buying a building maintenance unit from an overseas manufacturer: the distance, delivery-chain, documentation, and payment-structure questions that protect the owner between order and acceptance.

Read article →

07

BMU Beneficial Use and Construction Use: Separating Interim Use from Acceptance

Beneficial use before acceptance is complete and construction use after SAT: separating interim use from acceptance, the records each custody transition needs, and what the evidence can establish about early-service conditions.

Read article →

08

Retrofitting and Replacing Permanent Access Systems: The Second Installation Is the One the Owner Runs

Retrofit or replace an aging BMU or permanent access system: why the engineering case comes before procurement, the five drivers of the decision, owner-direct procurement, and the acceptance record the retrofit should leave behind.

Read article →